Air sample breathing zone
Air sample breathing zone











The typical operating flow range is 1 to 3 CFM (10 – 100 LPM). Please consult the product specification for the design temperature and the installation category. The LV-14ME Air Sampling System is designed for continuous indoor operation. The pump is mounted on a mobile cart with two rubber wheels to permit mobile transportation of the unit. The oil-less pump requires no lubrication to maintain optimal efficiency during its service life. This system allows the pump to work at a minimum head drop at all times permitting it to run cooler thus extending its lifetime. The regulator holds a constant pressure drop across an in-line orifice by varying the flow through a bypass valve into the pump. FSHD-29A Constant airflow maintained with a Telescoping sampling gooseneck permits easy adjustment to breathing zone levels. The LV-14ME air sampler includes a 1/4 HP oil-less, carbon vane vacuum pump with a constant airflow regulator for use where a nearly constant airflow is desirable. The adjustable gooseneck permits sampling at heights varying from 122 cm – 213 cm (4′ to 7′) above floor level. A simple rotameter may be used in the field or a digital flowmeter.Model LV-14ME is a cart mounted low volume air sampler with an adjustable, aluminum sampling gooseneck.

air sample breathing zone

This needs to be set using a calibrator pre-sampling and post sampling. NIOSH, OSHA, MDHS) will recommend a flow rate for sampling. Tracer gas concentrations were measured on a 60-sized mannequin holding a pure sulfur hexafluoride source in its hands at waist height while it stood in a. The sorbent tubes are desorbed either chemically or thermally and for an impinger/bubbler, the sampled liquid is analysed, generally by Gas chromatography. Here is a typical sample train for an impinger/bubbler:Īfter sampling the tubes or the sampled liquid are sealed and sent off to a laboratory for further analysis. Impingers and bubblers can be positioned in an area, held or mounted in a holster. Bubblers are open or fritted to increase the surface area so the gases are absorbed into solution. Impingers have a tapered outlet which allows particulate matter to exit at high velocity, hit the flask bottom and be captured in solution. This is a means of sampling replacing the solid sorbent tube with a liquid. The two layers are analysed separately and if the ‘back up’ layer is more than 10% of the main layer, the tube is deemed to be saturated and another sample must be taken varying the parameters (time, flow rate, size of tube etc.) Samples should be taken with the tube in a near vertical position on the body. Most tubes have two layers of material where the smaller layer is the ‘back up’ and should be closest to the sampling pump inlet. Also please refer to your standard method to find out which sorbent tube you require or search on the Hazard Pages. Please refer to the Sorbent Tube pages for more information. Charcoal is the most common sorbent material but Silica Gel, Chromopak, Tenax and others are also used dependent on the standard method. Flow rate needs to be set pre and post sampling.Ī sorbent tube contains a material which adsorbs the vapour or gas onto its surface during sampling.

air sample breathing zone

Apex2 with a Constant Pressure Controller and Low Flow Adaptor. Generally the flow is lower (typically 20-100ml/min) and so either a dedicated low flow pump may be used or a medium flow pump, i.e.

air sample breathing zone

The ends of the sorbent tube are broken off and inserted into a tube holder which is then connected to a personal sampling pump. Solvents, gases and vapours are sampled actively in a similar way to particulates but instead of filter and head, a sorbent tube is used or sometimes a bubbler/impinger.Ībove is a typical sample train using a sorbent tube. Please consult your standard method or the Hazard Search to find out what equipment you need. These are sealed badges which are opened for sampling, worn on the person for the recommended time, sealed and sent off for analysis. It is also possible to measure background exposure via Diffusive or Passive sampling. A typical sampling train for personal monitoring would look like this with the sampler mounted in the breathing zone įor grab samples of gases, a gas sampling bag is used, e.g. For particulates and fumes it would be a filter paper or suitable solid media and for gases and vapours through a sorbent tube or sometimes an impinger/bubbler. In general terms we draw a known volume of air using a sampling pump through a suitable sampling medium. Inhalation is usually the most significant route of entry into the body and so monitoring the air they breathe is vitally important. Many industrial and construction sites have the potential to expose their staff to harmful dust or vapours and gases.













Air sample breathing zone